Продолжая использовать сайт, вы даете свое согласие на работу с этими файлами.
1,2-Dichlorotetrafluoroethane
| |||
Names | |||
---|---|---|---|
Preferred IUPAC name
1,2-Dichloro-1,1,2,2-tetrafluoroethane | |||
Other names
R-114, CFC-114, halon 242, cryofluorane, Freon 114, Genetron 114, Refrigerant 114
| |||
Identifiers | |||
|
|||
3D model (JSmol)
|
|||
ChEMBL | |||
ChemSpider |
|
||
ECHA InfoCard | 100.000.853 | ||
EC Number |
|
||
PubChem CID
|
|||
RTECS number |
|
||
UNII | |||
UN number | 1958 | ||
CompTox Dashboard (EPA)
|
|||
| |||
| |||
Properties | |||
C2Cl2F4 | |||
Molar mass | 170.92 g/mol | ||
Appearance | colorless gas | ||
Odor | faint, ether-like (high concentrations) | ||
Density | 1.455 g/cm3 | ||
Melting point | −94 °C (−137 °F; 179 K) | ||
Boiling point | 3.5 °C (38.3 °F; 276.6 K) | ||
0.01% | |||
Vapor pressure | 1.9 atm (21°C) | ||
Hazards | |||
Occupational safety and health (OHS/OSH): | |||
Main hazards
|
Ozone depletor | ||
GHS labelling: | |||
Warning | |||
H280, H420 | |||
P410+P403, P502 | |||
Flash point | nonflammable | ||
Lethal dose or concentration (LD, LC): | |||
LC50 (median concentration)
|
720,000 ppm (rat, 30 min) 700,000 ppm (mouse, 30 min) 750,000 ppm (rabbit, 30 min) |
||
NIOSH (US health exposure limits): | |||
PEL (Permissible)
|
TWA 1000 ppm (7000 mg/m3) | ||
REL (Recommended)
|
TWA 1000 ppm (7000 mg/m3) | ||
IDLH (Immediate danger)
|
15000 ppm | ||
Except where otherwise noted, data are given for materials in their standard state (at 25 °C [77 °F], 100 kPa).
|
1,2-Dichlorotetrafluoroethane, or R-114, also known as cryofluorane (INN), is a chlorofluorocarbon (CFC) with the molecular formula ClF2CCF2Cl. Its primary use has been as a refrigerant. It is a non-flammable gas with a sweetish, chloroform-like odor with the critical point occurring at 145.6 °C and 3.26 MPa. When pressurized or cooled, it is a colorless liquid. It is listed on the Intergovernmental Panel on Climate Change's list of ozone depleting chemicals, and is classified as a Montreal Protocol Class I, group 1 ozone depleting substance.
When used as a refrigerant, R-114 is classified as a medium pressure refrigerant.
The U.S. Navy uses R-114 in its centrifugal chillers in preference to R-11 to avoid air and moisture leakage into the system. While the evaporator of an R-11 charged chiller runs at a vacuum during operation, R-114 yields approximately 0 psig operating pressure in the evaporator.
Manufactured and sold R-114 was usually mixed with the non symmetrical isomer 1,1-dichlorotetrafluoroethane (CFC-114a), as separation of the two isomers is difficult.
Dangers
Aside from its immense environmental impacts, R114, like most chlorofluoroalkanes, forms phosgene gas when exposed to a naked flame.
External links
- Material Safety Data Sheet from Honeywell International Inc., dated 22 August 2007.
- CDC - NIOSH Pocket Guide to Chemical Hazards
Inhalational | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Injection |
|
||||||||||||||
|
Authority control: National |
---|